§411.6 IT-system — first fault withstand capability

In an IT system, the supply neutral is isolated from earth or earthed via a high impedance (Z_IT — several kΩ or more), while exposed conductive parts of the installation connect to a separate earth electrode. This means a first L-PE insulation fault produces only a small leakage current, limited by Z_IT, and enclosure voltage stays below the U_L = 50 V AC threshold. **Automatic disconnection after the first fault is not required** — the installation can keep running, critical for hospitals and continuous-process sites. **The condition must be met**: R_A × I_d ≤ U_L, where R_A is the earth resistance of exposed parts and I_d is the first-fault current. **An insulation monitoring device (IMD) must be installed**, giving a continuous audible and/or visual alarm on the first fault for prompt corrective action (in medical locations, additionally with an insulation fault location system IFLS for faster defect pinpointing). After the first fault is detected, a second fault must be cleared by overcurrent protective devices, RCDs, or residual current monitors (RCM): the condition Z_S ≤ U / (2 × I_a) applies to the fault loop between two phases via PE, where U = U_0 with a distributed neutral conductor (TN-like behavior, §411.4) or U = U_LL (line voltage) without a distributed neutral. Disconnection times follow Table 41.1 for the relevant system U_0.
EB-authored summary for design convenience — NOT normative IEC text. Official standard IEC 60364-4-41:2005+A1:2017 available at webstore.iec.ch →.
Explain in plain words
In plain words
AI-generated — may contain inaccuracies

The IT system is designed so that the first insulation fault does not interrupt operation — this is important for hospitals and continuous processes. The source neutral is either isolated from earth or connected via a high impedance, so the first fault to the enclosure produces only a small leakage current and the voltage on enclosures remains safe. Therefore, automatic disconnection after the first fault is not required, but an insulation monitoring device (IMD) must be installed to immediately give a signal so that personnel can locate and rectify the defect. Danger arises upon a second fault on a different phase — then protection (circuit breakers, RCDs) must disconnect within the standardized time. In practice: IT is rare in domestic installations, but if you maintain one — the main thing is not to ignore the IMD signal, because the first 'silent' defect already halves the protection.